Title: Six Unpatched Pre-Authentication RCE Flaws Found in Danfoss AK-SM800A Refrigeration Controllers
Summary: Dutch security consultancy Midnight Blue reports that researcher Carlo Meijer found six pre-authentication remote code execution vulnerabilities in Danfoss AK-SM800A refrigeration controllers in under an hour of casual manual firmware review — all are stack-based buffer overflows in a codebase that ships without stack canaries or PIE, and no CVE identifiers have been assigned yet while coordinated disclosure with Danfoss is ongoing. All versions up to and including 5.3.2 are affected; per The Hacker News, the vendor’s newest 5.4.0 firmware package, dated November, does not fix the flaws either, and Danfoss’s advisory page listed no advisory for them as of today. Five of the flaws sit in web request handlers that require no login inside a program running as root, through which the researchers demonstrated full code execution as root on older firmware 3.3.0, finding the same bugs in 5.3.2; the sixth lives in the gateway that enforces Strict session control — the login protection meant to fence off the web attack surface — which crashed in their emulated 5.3.2 testing and could with more work become yet another pre-auth RCE. With code running as root and no secure boot enabled on the device, an attacker could alter temperature settings, start defrost cycles, hide the activity from logs, plant an implant that survives a factory reset and firmware update, or brick the controller outright. No exploitation of these six specific flaws has been reported — Germany’s BSI says it has no information of such use — but the controllers were the target of attack waves across Europe starting October 11 in France, with a second wave from early November, causing unwanted defrost cycles and spoiled stock. In response to the attack waves, Belgium, Ireland and Germany each put out cyber guidance this week pressing operators to stop exposing the controllers’ management interfaces to the open internet; the Belgian and Irish advisories note that firmware updates, default-password changes, or Strict mode alone are not enough, and recommend finding any controller reachable from the internet — including via 4G/5G maintenance modems — giving remote access only through a VPN or protected internal network, and checking setpoints, defrost schedules, alarm settings, user accounts and remote-access settings for tampering. Midnight Blue argues against piecemeal patching of a fundamentally flawed codebase and says exposure reduction through VPNs, private APNs, or highly restrictive IP whitelists is the only meaningful mitigation.
References: